<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-23 08-45-37
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.30 MHz 5/5, 83 dBuV 00s10s
Pilot RDS Phase Difference
6.0 kHz 4.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 74 kHz 19097 0,6546
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
6,6 dBr 7,34 dBr 7,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"00s10s " 249D 0 (No PTY) 1 0 1 1 --:--
RT
" "
AF EON
-
FM Scope Max at: 74 kHz MIN: 10 kHz % above 76 kHz: 0,6546 Acquired: 2026/01/23 8.44.32 Total samples: 19097 Equivalent time: 0:15:54 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000 4000
FM Scope MAX: 7,8 dBr MIN: 6,6 dBr AVE: 7,34 dBr % above 12,2 dBr: 0,0 Last value: 7,5 dBr (2026/01/23 8.44.31) 08.30 08.32 08.34 08.36 08.38 08.40 08.42 08.44 0 2 4 6 8 Pm [dBr]